英国tti CPX400SA直流电源,CPX400SA价格:
Bench/System DC Power Supply, PowerFlex Regulation, Smart Analog Controls Single Output, 60V/20A 420W, USB, RS232, LAN & GPIB Interfaces
  • PowerFlex design gives variable voltage and current combinations within a maximum power range
  • Up to 60 volts and up to 20 amps
  • 180 watts or 420 watts maximum per output
  • Isolated outputs can be wired in series or parallel
  • Constant voltage or constant current operation
  • Settings Locking (S-Lock)
  • PowerFlex or fixed-range operation
  • Variable OVP trips
  • Selectable remote sense terminals
  • Compact quarter or half rack 3U case size
  • Isolated analogue remote control (CPX400SA only)
  • RS232, USB, GPIB & LXI compliant LAN (P models only)

  • 英国tti CPX400SA直流电源,CPX400SA价格:
    Single output 420 watt PowerFlex DC PSUs High power single output CPX400 power envelopeThe CPX400S is a single output version of the best selling CPX400D.The ultra-compact design (quarter rack 3U) takes up minimum space for bench or system use.

    PowerFlex regulation enables the 420 watts of power to be configured to suit each specific application. See the power curve below for more information

    Three versions are available, manual control only (S), with isolated analogue remote control (SA), or with digital remote control via USB, RS232, GPIB and LAN (SP).
    英国tti CPX400SA直流电源,CPX400SA价格:
    CPX OVP button
    Over-voltage trip When in manual operation mode, the CPX Series has an OVP control that is set from the front panel (individually set per output on dual output models).
    In bus controlled mode (CPX200DP, CPX400SP and CPX400DP only), this is replaced by a bus programmable OVP protection that can be set in 0.1V increments
    Over-current trip The over-current trip is available only on the CPX200DP, CPX400SP and CPX400DP models and is only active when in bus controlled mode. OCP can be set in increments of 10mA.
    V/I settings View
    synchro<ems></ems>nous on/off button
    Individual DC output switches The individual DC output switches allows you to set up voltage and current levelsbefore you connect to the load.
    Surprisingly, many laboratory power supplies lack this basic feature, and require you to use the AC power switch for connection and disconnection.
    Synchronous switching of both outputs For dual output models, the Synchronous On/Off button is in addition to the individual switches for each output, and allows both outputs to be turned on or off synchronously by a single button press.
    Synchronous switching of the outputs is of increasing importance for circuitry which can be damaged if one voltage rail is present without the other.
    View Settings button When the output is on, the meters show the actual voltage and current.
    Pressing the View V/I Settings button enables the limit settings to be checked and adjusted at any time.