产品名称: 英国tti EX354RD直流稳压电源,EX354RD价格
产品型号: EX354RD
品牌: 1532
产品数量:
产品单价: 面议
日期: 2023-11-23

英国tti EX354RD直流稳压电源,EX354RD价格的详细资料

英国tti EX354RD直流稳压电源,EX354RD价格:
Bench DC Power Supply, Mixed-mode Regulation, Analog Controls 18V/10A Single
  • Single outputs, 35V/, 18V/10A, 42V/10A, 20V/20A
  • Dual or triple outputs, 35V/4A
  • Independent digital voltage and current meters for each output with 4 digit resolution
  • Switchable local or remote sensing
  • Constant voltage or constant current operation
  • Variable 1.5 - 5.0V auxiliary output at (EX354RT)
  • Compact design uses less bench space
  • Silent fan-free cooling (not EX202R/EX4210R)
  • DC output switches, automatic mode indication
  • RS232 or USB controlled models available (35V/ single)
  • Multi-mode dual model 2x(75V/2A) or 75V/4A or 150V/2A

英国tti EX354RD直流稳压电源,EX354RD价格:
Power, Precision, Simplicity The EX-R series has been extended by incorporating models from the best selling EX series. By adding four digit meters and switchable remote sensing, the EX-R series offers much higher precision whilst retaining the simplicity of operation which many bench-top power supply users prefer.

Six models are offered including single, dual and triple outputs and covering a power range of 175 watts up to 420 watts. Models
Model Output 1 Output 2 Output 3 Power
EX355R 35V/ 175W
EX1810R 18V/10A 180W
EX2020R 20V/20A 400W
EX4210R 42V/10A 420W
EX354RD 35V/4A 35V/4A 280W
EX354RT 35V/4A 35V/4A 1.5 - 5V/ 5 A 305 W
英国tti EX354RD直流稳压电源,EX354RD价格:
TECHNICAL SPECIFICATIONS
OUTPUT
Voltage/Current Ranges
EX355R 0 to >35V; 0 to > (175W nominal power)
EX1810R 0 to >18V; 0 to >10A (180W nominal power)
EX2020R 0 to >20V; 0 to >20A (400W nominal power)
EX4210R 0 to >42V; 0 to >10A (420W nominal power)
EX354RD 2 x (0 to >35V; 0 to >4A) (280W nominal power)
EX354RT 2 x (0 to >35V; 0 to >4A) plus <1.5 to >5.0V @ (305W nominal power)
Output Setting & Control
Voltage Setting By coarse and fine controls
Current Setting By single logarithmic control
Output Mode Constant voltage or constant current with automatic cross-over. CC indicator in constant current mode.
Output Switch Electronic, non isolating. Preset voltage and current limit displayed when Output off
Output Performance
Ripple & Noise Typically < 2 mV rms , <10mV pk-pk , (EX355R, EX354RD, EX354RT)
Typically <2 mV rms, <20mV pk-pk (EX1810R, EX2020R, EX4210R)
CV mode, 20MHz bandwidth
Load Regulation <0.01% of maximum output for a 90% load change (using remote sense)
Line Regulation <0.01% of maximum output for 10% line change
Transient Response <200us to within 50mV of setting for a 5% to 95% load change
Temp. Coefficient (Voltage) typically <100ppm/°C
Output Protection
Output Protection Outputs will withstand forward voltages up to 40V (EX355R, EX354RD,& EX354RT); 22V (EX1810R); 25V (EX2020R); 48V (EX4210R). Reverse protection by diode clamp for currents to 3A.
Output Connections
Output Terminals Universal 4mm safety binding posts on 19mm (0.75") spacing. Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires.
Remote Sense
Sense Selection Voltage sensing is selected as Local or Remote by front panel switch
Sense Terminals Sprung loaded screw-less terminals

METER SPECIFICATIONS
Display Type Dual 4-digit meters, 14mm (0.56") LED
Voltage Meter
Resolution 10mV
Accuracy 0.3% of reading +/- 3 digits
Current Meter (EX355R,EX354RD, EX354RT)
Resolution 1mA
Accuracy 0.5% of reading +/- 3 digits
Current Meter (EX1810R, EX2020R, EX4210R)
Resolution 10mA
Accuracy 0.6% of reading +/- 3 digits

AUXILIARY OUTPUT (E X354 RT only)
Voltage Variable <1.5V to >5V by front panel control
Meter accuracy 0.3% +/- 4 digits
Current limit 5 A minimum.
Load regulation < 0.5 % for 90% load change
Line regulation <0. 1 % for 10% line voltage change
Ripple & Noise Typically < 2 mV rms, <10 mV pk-pk (20MHz bandwidth)
Output Protection Output will withstand up to 7V forward voltage. Diode clamp reverse protection for currents up to 3A.
Output Terminals Universal 4mm safety binding posts on 19mm (0.75") spacing
Status Indication UNREG lamp

GENERAL
AC Input
EX354RD, EX354RT 110V to 240V 50/60Hz (universal input). Installation Category II
Other Models 230V AC +/- 10% 50/60Hz; 115V to order. Installation Category II
VA Ratings
EX810R, EX355R 400VA
EX354RD, EX354RT 500VA
EX2020R, EX4210R 800VA
Temperature & Environmental
Operating Range +5°C to +40°C, 20% to 80% RH
Storage Range -40°C to + 70°C
Environmental Indoor use at altitudes up to 2000m, Pollution Degree 2
Cooling
EX1810R, EX355R, EX354RD, EX354RT fan-less convection cooling
EX2020R, EX4210R fan assisted using low-noise brushless dc fan
Safety & EMC
Safety Complies with EN61010-1
EMC Complies with EN61326

PHYSICAL
Size
Single output models 140x160x320mm (WxHxD)
Dual and triple output models 260x160x 320 mm (WxHxD)
Weight
EX810R, EX355R 3.0kg
EX2020R, EX4210R 3.6kg