您当前的位置:首页 » 产品展示 » 直流稳压电源 » 英国tti EL301R,EL301R直流稳压电源
产品名称: | 英国tti EL301R,EL301R直流稳压电源 |
产品型号: | EL301R |
品牌: | 1532 |
产品数量: | |
产品单价: | 面议 |
日期: | 2024-09-19 |
英国tti EL301R,EL301R直流稳压电源的详细资料
英国tti EL301R,EL301R直流稳压电源:OUTPUT | |
---|---|
Voltage/Current Ranges | |
EL301R | 0 to >30V; 0 to >1A (30W nominal power) |
EL183R | 0 to >18V; 0 to >3.3A (60W nominal power) |
EL302R | 0 to >30V; 0 to >2A (60W nominal power) |
EL561R | 0 to >56V; 0 to >1.1A (60W nominal power) |
EL155R | 0 to >15V; 0 to > (75W nominal power) |
EL303R | 0 to >30V; 0 to >3A (90W nominal power) |
EL302RD | 2 x (0 to >30V; 0 to >2A) (120W nominal power) |
EL302RT | 2 x (0 to >30V; 0 to >2A) plus 1.5 to 5.0V @ 2A (130W nominal power) |
Output Setting & Co |
|
Voltage Setting | By coarse and fine controls. |
Current Setting |
By single logarithmic co |
Output Mode |
Co |
Output Switch | Electronic, non isolating. Preset voltage and current limit displayed when Output off. |
Output Performance | |
Ripple & Noise | Typically <1mV rms, (CV mode, 20MHz bandwidth). |
Load Regulation | <0.01% of maximum output for a 90% load change (using remote sense) |
Line Regulation | <0.01% of maximum output for 10% line change |
Transient Respo |
: <50us to within 50mV of setting for a 5% to 95% load change |
Temp. Coefficient (Voltage) | typically <100ppm/°C |
Output Protection | |
Output Protection | Output will withstand forward voltages of up to 20V above rated output voltage. Reverse protection by diode clamp for currents to 3A. |
Output Co |
|
Output Terminals | Universal 4mm safety binding posts on 19mm (0.75") spacing. Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals and bare wires. |
Remote Sense | |
Sense Selection | Voltage sensing is selected as Local or Remote by front panel switch |
Sense Terminals | Sprung loaded screw-less terminals |
METER SPECIFICATIONS | |
---|---|
Display Type | Dual 4-digit meters, 14mm (0.56") LED |
Voltage Meter | |
Resolution | 10mV |
Accuracy | 0.3% of reading +/- 3 digits |
Current Meter | |
Resolution | 1mA |
Accuracy | 0.5% of reading +/- 3 digits |
AUXILIARY OUTPUT (EL302RT only) | |
---|---|
Voltage |
Variable <1.5V to >5V by front panel co |
Meter accuracy | 0.3% +/- 4 digits |
Current limit | 2A minimum |
Load regulation | <3% for 90% load change |
Line regulation | <0.2% for 10% line voltage change |
Ripple & Noise | Typically <5mV rms, <15mV pk-pk (20MHz bandwidth) |
Output Protection | Output will withstand up to 7V forward voltage. Diode clamp reverse protection for currents up to 3A. |
Output Terminals | Universal 4mm safety binding posts on 19mm (0.75") spacing |
Status Indication | UNREG lamp |
GENERAL | |
---|---|
Input | |
AC Input | 230V AC or 115V AC +/- 10%, 50/60Hz. Installation Category II |
VA Ratings: | |
EL301R | 85 VA |
EL302R, EL302P, EL183R, EL561R | 160VA |
EL155R, EL303R | 250VA |
EL302RD, EL302RT | 320VA |
Temperature & Enviro |
|
Operating Range | +5°C to +40°C, 20% to 80% RH |
Storage Range | -40°C to + 70°C |
Enviro |
Indoor use at altitudes up to 2000m, Pollution Degree 2 |
Cooling |
Silent fan-less co |
Safety & EMC | |
Safety | Complies with EN61010-1 |
EMC | Complies with EN61326 |
PHYSICAL | |
---|---|
Size | |
Single output models |
140 |
Dual and triple output models |
260 |
Weight | |
EL301R | 3.4kg |
EL302R, EL302P, EL183R, EL561R | 4.4kg |
EL155R, EL303R | 5.0kg |
EL302RD, EL302RT | 7.5kg |